32mm Sealed Liquid Transmission Cells for FTIR Spectroscopy

32mm Circular Sealed Liquid Transmission Cells

32mm Circular Sealed Liquid Transmission Cells
REFLEX Analytical offers circular sealed liquid cells with a 13mm FTIR circular aperture (as pictured). Each cell consists of a front plate with a choice of horizontal or vertical luer-lock fittings and PTFE plugs, a back plate and a 32mm circular drilled and undrilled window assembly. Tubing connections are an option for flow through analysis (refer to the drop down menu). Choose from the following standard pathlengths: 0.015mm, 0.025mm, 0.05mm, 0.10mm, 0.20mm, 0.50mm, 1.0mm, 5.0mm and 10.0mm. If required for quantification, cell calibration and matching is available as an optional service and should be indicated upon ordering.

Available transmission window materials include BaF2 Barium Fluoride, CaF2 Calcium Fluoride, Cesium Iodide CsI, KBr Potassium Bromide, KRS-5 Thallium Bromide Iodide, NaCl Sodium Chloride, IR-SiO2 IR Quartz, ZnSe Zinc Selenide and ZnS Zinc Sulfide.

After the initial purchase of a sealed liquid cell, you may use the liquid cell holder and choose from sealed sandwich cells with flow through tubing connections, horizontal or vertical luer-lock fittings for future sampling needs. Refer to http://www.reflexusa.com/32lisace.html

REFLEX Analytical also offers a sealed cell reconditioning service in an effort to recycle and preserve resources.
Send Page to Friend

KBr 32mm Sealed Liquid Cell
$495.00
13XX-32ROHS
Path:  Fitting: 
NaCl 32mm Sealed Liquid Cell
$495.00
18XX-32ROHS
Path:  Fitting: 
BaF2 32mm Sealed Liquid Cell
$595.00
05XX-32ROHS
Path:  Fitting: 
CaF2 32mm Sealed Liquid Cell
$595.00
07XX-32ROHS
Path:  Fitting: 
IR Quartz 32mm Sealed Liquid Cell
$750.00
20XX-32ROHS
Path:  Fitting: 
ZnS 32mm Sealed Liquid Cell
$875.00
22XX-32ROHS
Path:  Fitting: 
ZnSe 32mm Sealed Liquid Cell
$875.00
23XX-32ROHS
Path:  Fitting: 
CsI 32mm Sealed Liquid Cell
$1,295.00
10XX-32ROHS
Path:  Fitting: 
KRS-5 32mm Sealed Liquid Cell
$1,995.00
15XX-32ROHS
Path:  Fitting: 
Cell Calibration & Matching
Liquid cell calibration is required for quantitative analysis but if performing qualitative investigations, then cell calibration is not necessary.

REFLEX Analytical's standard liquid cell calibration is within 10% of the cell's nominal pathlength for a single cell. If two or more cells are ordered and cell calibration & matching is required, then the cells are matched within 3% of the each cell's calibrated pathlength.
CALIB-M